TECHNICAL
LIGHTWEIGHT
PENNY PANELS are easy to handle, erect and transport – providing flexibility in design and significant structural cost savings.
STRONG AND DURABLE
PENNY PANEL withstands knocks, scrapes and rough treatment. The panels are also suitable for seismic and cyclone prone zones.
FIRE RESISTANT
Wherever fire walls are needed, PENNY PANEL allows flexibility in design.
Its fire ratings are equivalent to those for masonry, with a marked
improvement in look and feel.
WATER AND TERMITE – RESISTANT
PENNY PANEL is a termite resistant panel and its excellent water resistant
properties withstand adverse weather conditions.
EASY TO INSTALL
PENNY PANEL arrive ready to install. The tongue-and-groove system allows rapid assembly, with panels being slid between top and bottom steel or aluminium sections and locked together. Panels can be cut with power tools and are ready to use or to fi nish with any decorative treatment.
INSULATING
PENNY PANELS provide excellent thermal and sound insulation. The sound transmission coefficient and thermal resistance is similar to masonry.
SAVES SPACE
Slim PENNY PANELS (50 or 75 mm) leave you with extra usable floor space without compromising on insulating properties.
SAVES TIME
PENNY PANELS simplicity suits rapid construction techniques. Factory cured
panels mean no on-site curing.The smooth surfaces are ready for surface finishing if desired.
SAVES MONEY
As installation does not require skilled labour or plaster coating, you save by not employing wet trades or other trades. Transport costs are reduced, due to the lightweight construction. Cost per m2 is also far lower than masonry.
50mm | 75mm | 100 mm panel | TEST DETAILS | ||
---|---|---|---|---|---|
WEIGHT | 39KG/M2 | 54KG/M2 | 63KG/M2 | ||
AXIAL LOAD BEARING | 53KN/Panel | 111KN/Panel | 1220KN/Panel | UNIVERSITY OF NSW | |
BENDING | 1.2 KN/M | 3.3KN/M | 5KN/M | UNIVERSITY OF NSW | |
SOUND TRANSMISSION (Rw ) | 38 dB | 45dB | 50 dB | Test done by Penny World Engineers | |
SOUND TRANSMISSION (Rw + Ctr ) | 34 dB | 41 dB | 45 dB | Test done by Penny World Engineers | |
Fire resistance | 1 hour | 2 HOURS | 3 HOURS | Test Done By CSIRO | |
THERMAL CONDUCTIVITY(K) | 0.28 W/M2 K | 0.25 W/M2 K | 0.20 W/M2 K | BS874 Part 2 | |
THERMAL TRANSMISSION U VALUE | 2.1 W/M2 K | 2.6 W/M2 K | 2.8 W/M2 K | Test done by Penny World engineers | |
|